Type OM-IN OM-2N LT-20W OM-3N(W) LT-51W LT-61W LT-81
Fuel Consumption(kg/h) 5¡«10 8¡«20 8¡«20 12¡«30 18¡«45 20¡«55 25¡«75
Power Source 1¦Õ220V 1¦Õ220V 1¦Õ220V 1¦Õ220V 3¦Õ380V 3¦Õ380V 3¦Õ380V
Power of Motor(kw) 0.15 0.25 0.25 0.25 0.4 0.75 1.0
Control On -Off On -Off Two phases On -Off Two phases Two phases Two phases Two phases
Oil pipe Oil in 1/4 1/4 1/4 1/4 3/8 3/8 3/8
  Oil out              
Nozzle (standard) 2.5¡Á600 3.75¡Á600 20¡Á600¡Á2 7¡Á600(3.5¡Á600¡Á2) 4.5¡Á600¡Á2 5¡Á600¡Á2 8¡Á600¡Á2
Flame diameter(mm) 110¡«130 140¡«160 140¡«160 200¡«300 300¡«400 350¡«450 400¡«500
Flame length(mm) 200¡«250 350¡«400 350¡«400 500¡«700 600¡«750 700¡«850 750¡«1000
Installation Size (Refer to the below illustration for reference) A(mm) 88 114 101 127 152 152 152
B(mm) 180 220 220 270 224 224 240
C(mm) 100 120 120 150 120 120 120
D(mm) 11 12 12 12 12 12 14
E(mm) 135 185 185 240 195 195 210
Note: heat value of diesel oil is 10 thousand kcal. per kilo.
  Please feel free to contact our technician if you have any problem.
 
 
Type GOM-1N(W) GOM-2N(W) GOM-3N(W) AG-25WS AG-30WS AG-40WS AG-45WS AG-60WS
output£¨thousand kilocalorie £©
10
20
30
25
30
40
45
60
Fuel Rating LPN
4.26
8.51
12.77
10.64
12.77
17.02
19.15
25.53
  LNG
11.11
22.22
33.33
27.78
33.33
44.44
50
66.67
Control
On - Off
(Two phases)
On - Off
(Two phases)
On - Off
(Two phases)
pilot flame
(Two phases)
pilot flame
(Two phases)
pilot flame
(Two phases)
pilot flame
(Two phases)
pilot flame
(Two phases)
Power Source:
1¦Õ220V
1¦Õ220V
1¦Õ220V
3¦Õ220V
3¦Õ220V
3¦Õ220V
3¦Õ220V
3¦Õ220V
Power of Motor
(kw)
0.15
0.25
0.25
0.4
0.4
0.75
0.75
1.0
Flame diameter
(mm)
90¡«110
120¡«150
150¡«180
170¡«200
170¡«250
200¡«300
250¡«300
300¡«400
Flame length
(mm)
200¡«250
350¡«500
400¡«600
400¡«600
400¡«600
450¡«700
500¡«800
700¡«1100
Connection Size LPG
3/4
3/4
3/4
1
1
1
1
5/4
LNG
3/4
3/4
5/4
1
1
5/4
5/4
2
Installation
Size
A(mm)
88
114
127
160
180
180
180
216
B(mm)
100
120
150
100
120
120
120
120
C(mm)
135
190
240
240
240
240
240
310
D(mm)
180
220
260
270
270
270
270
340
Note: Heat value of LPG is 23.5 thousand kcal. Gas supply pressure is 280mm water-column.
  Heat value of LPG is 9 thousand kcal. Gas supply pressure is 200mm water-column.
H eat value of diesel oil is 10 thousand kcal. per kilo.
AG series GOM-1N£¨W£©¡¢2N£¨W£© GOM-3N£¨W£©  
   
Japan Headquarter: Olympia Kogyo Co.,Ltd
Address: 7-33-28, Fujumi-cho, Tachikawa City, Tokyo, Japan
Tel£º(+81)42-525-3421
Fax£º(+81)42-527-5003

China Headquarter: Shenzhen Olympia Industrial Co. Ltd
Address;4F south,3-Building Dongxinkeitai Industrial Area, qiaoxiang Road,xiangmi Lake,Futian District, Shenzhen City,518040,China
Tel£º(+86)(0755)25515930 25515931 25515932
Fax£º(+86)(0755)25517393
Shanghai Sub Company:
Tel£º86-021-58382503 58382502 38910010
Fax£º86-021-58382505
COPYRIGHT©SHENZHEN OLYMPIA INDUSTRIAL CO.,LTD